Refrigerator repair in Houston, from warm shelves to iced-over coils.
- Fault found before any price
- One fixed price you approve
- 90-day parts warranty
Phones answered now
- 1You callany hour
- 23-hour windowagreed with you
- 3Fixed pricebefore any work
Free to request · 3 steps
Request a repair appointment
Takes about a minute. There is no charge to submit a request.
- Diagnosis
- The cause is identified before any price is given
- Approval
- One fixed price, and work begins only with your consent
- Hours
- Our phones are answered 24 hours a day
- Warranty
- Parts warranted for 90 days, labor for 30
- 1–3 hours
- Usual duration of a visit
- 30
- Refrigerator faults documented
- 37
- Manufacturers serviced
- 24/7
- Phones answered
Refrigerator problems
What your refrigerator is telling you
Open the symptom that matches yours. Each card lists the usual causes and the test we use to confirm one.
Refrigerator not coolingThe thermometer climbs past 40°F, milk feels warm and leftovers spoil sooner than they should. What makes this puzzling is that the interior light still works and the unit may sound as though it is running. A warm compartment only tells us that heat is no longer being carried away; the underlying cause may lie in airflow, the defrost system, a fan, the controls or the sealed system.
Usual causes
- The evaporator fan motor has stopped, so cold air stays trapped in the freezer
- A defrost failure has let frost smother the evaporator coil
- Dust and pet hair have built up thickly on the condenser coils
- The condenser fan behind the kick plate has seized
- A defective thermistor is giving the control an incorrect temperature
What we do
Our technician measures real temperatures in each compartment and at the evaporator, and confirms that both the condenser fan and the evaporator fan are turning. Where the coil is encased in frost, the defrost heater, the defrost thermostat and the control's output are each tested in sequence until the faulty component is identified.
Freezer compartment too warmFrozen meat yields under your thumb and ice cream loses its firmness. In most refrigerators the freezer produces the cold air for both compartments, so the fresh-food side usually begins to warm soon afterward. If the freezer is holding at 15–20°F rather than 0°F, it should be looked at on the same day.
Usual causes
- An open defrost heater has left the coil packed in ice
- Ice is obstructing the freezer fan blade, or the fan motor has failed
- A weakening start relay lets the compressor run only in brief bursts
- A leak in the sealed system has reduced the refrigerant charge
- An overfilled bin or a distorted gasket is holding the door slightly open
What we do
We remove the rear freezer panel and study the coil and its frost pattern, which separates a defrost fault from a refrigerant fault. Next we measure the fan, the relay and the compressor's current draw, and we replace only the component that does not pass its test.
Ice maker produces no iceThe bin remains empty, or a handful of cubes appear before production stops. In some cases the ice maker itself is sound but water is not reaching it; in others the freezer is not cold enough for a cycle to begin. Working through water supply, then freezer temperature, then the module avoids unnecessary part replacement.
Usual causes
- Ice has sealed the fill tube at the point where it enters the freezer
- The water inlet valve coil is open, or its inlet screen is blocked
- The freezer is above roughly 10°F, so the mold never gets cold enough to harvest
- The motor or gear inside the ice maker module has failed
- The shut-off arm or optical sensor is stuck reporting a full bin
What we do
We begin by verifying water pressure at the inlet valve and confirming the freezer is cold enough to start a harvest. The module is then put through a manual test cycle. Whichever stage fails, whether filling, freezing or ejecting, shows us which component needs replacing: the ice maker module itself, the fill tube or the inlet valve.
Water leaking onto the floorWater beneath a refrigerator may originate inside the cabinet or behind it. Clear water toward the front most often indicates a backed-up defrost drain, while dampness at the rear generally leads to the supply line or the inlet valve. In either case, dry the floor promptly so moisture does not work into hardwood or the subfloor.
Usual causes
- Ice or food debris has blocked the defrost drain tube
- The drain pan is cracked or has moved out of position
- The plastic supply line or its compression fitting is leaking at the inlet valve
- The water filter head or its housing has cracked
- The cabinet leans forward, so meltwater bypasses the drain
What we do
We follow the water to its origin by placing dry towels at the front, at the drain pan and beneath the valve. A clogged drain is cleared and flushed through with warm water. Where a supply line, filter head or fitting has cracked, we fit a new one and pressure-test the joint before sliding the refrigerator back into place.
Water dispenser not flowingPressing the paddle produces nothing, or only a brief splutter. If ice production continues as usual, the fault is easier to locate, because the dispenser relies on its own valve, its own switch and tubing that is routed through the door hinge.
Usual causes
- The water line running inside the door has frozen
- The dispenser half of the dual inlet valve has failed
- The paddle switch or the dispenser control board is not supplying power
- The filter is not fully seated, or the bypass plug is missing
- The household shut-off valve is partly closed, or a saddle valve is clogged
What we do
We check whether voltage reaches the valve while the paddle is held and measure flow on the dispenser circuit. A frozen line in the door is thawed and the source of the cold spot corrected. When the valve solenoid or the paddle switch has failed, we install a new one and confirm flow at the dispenser.
Unusual or loud noisesHumming, clicking and the occasional gurgle are part of a refrigerator's ordinary operation. A grinding, squealing or rattling sound that was not there before is another matter. Noting where it seems to come from, such as the freezer's rear wall, the lower back corner or behind the kick plate, helps identify which component is wearing.
Usual causes
- The evaporator fan blade is striking ice inside the freezer
- The bearings in the condenser fan motor are drying out
- Worn compressor mounts allow it to vibrate against the frame
- The drain pan or a loose length of tubing is rattling at the base
- The ice maker auger or dispenser motor is grinding
What we do
With the panels removed, our technician listens closely to locate the sound, then rotates each fan blade manually, feeling for any drag in the bearings. A worn fan motor is replaced, loose pans and tubing are secured, and any ice around the evaporator fan is traced to the defrost failure responsible for it.
Door gasket damaged or leakingClose the door on a dollar bill; if it pulls free with little resistance, warm air is entering the cabinet. Other signs include frost close to the door, moisture on the gasket and a refrigerator that runs noticeably longer than before. Even a small tear at one corner can produce these effects.
Usual causes
- Age has split the gasket at its corners
- The rubber has stiffened and no longer holds its shape
- The magnetic strip inside the gasket has lost strength
- Worn hinge parts have allowed the door to sag
- Food residue prevents the gasket from sitting flat
What we do
We inspect the full perimeter of the seal with a light test and correct the door's alignment before anything else, since a sagging door will quickly damage a new gasket. When the gasket is at fault, we fit a replacement matched to your model and warm it so it settles evenly against the cabinet.
Temperature keeps rising and fallingOn one day the lettuce is frozen, and on another the milk has turned warm. Inconsistent temperatures generally indicate that the refrigerator is misreading temperature or is not regulating its airflow correctly. It deserves attention before it becomes a food safety concern.
Usual causes
- The air damper control is sticking in the open or closed position
- A thermistor has drifted outside its normal resistance range
- Defrost cycles are running for too long or too frequently
- A relay on the main control board is chattering
- Crowded shelves are obstructing the air vents
What we do
We record temperatures across several cycles and check the thermistor's resistance against the manufacturer's chart. Those readings determine whether the damper, the sensor or the board relay must be replaced, and we clear any blocked vents so that air circulates properly again.
Runs without stoppingWhen a refrigerator never seems to cycle off, it is working beyond its normal load. It may still be holding temperature under strain, or it may be running steadily while gradually warming. In both situations the compressor wears more quickly and electricity use rises.
Usual causes
- Lint and dust are obstructing the condenser coils
- A leaking door gasket is admitting warm air
- A failing defrost system lets frost insulate the coil
- The condenser fan is turning slowly or has stopped
- The unit stands beside an oven or in a hot garage
What we do
Our technician cleans the condenser, verifies that its fan reaches full speed and examines the evaporator coil for frost. Gasket leaks and defrost components are tested after that, and we conclude by timing a complete cycle to confirm the compressor is switching off again.
Frost building on the freezer wallIn a frost-free freezer, a layer of snow-like frost should never form on the rear wall. If it does, the automatic defrost system has stopped doing its job. Within a week or two the frost restricts airflow and the fresh-food compartment begins to lose its cold.
Usual causes
- The defrost heater element has burned open
- The bi-metal defrost thermostat is stuck open
- The defrost timer or control board is not initiating defrost
- A door left open for a long period has loaded the coil with moisture
What we do
We melt away enough frost to reach the defrost components, then test the heater, the thermostat and the timer or board for continuity and output. After the failed part is replaced, we force a defrost cycle to confirm that the coil clears completely.
Food freezing in the fridge sectionDrinks at the back of a shelf freeze, eggs crack and lettuce collapses into a soft mass. This means the fresh-food compartment is receiving too much cold air or the temperature is being read incorrectly. Adjusting the dial to a warmer setting seldom resolves it for long.
Usual causes
- The air damper is stuck open
- The fresh-food thermistor is reading warmer than the actual temperature
- The temperature control is set too cold, or the dial itself is faulty
- Food is pressed against the cold-air outlet
- The control board is not closing the damper when it should
What we do
We observe how freely the damper door moves and measure the thermistor's resistance against a reference temperature. If the damper sticks or the sensor has drifted, that part is replaced, and shelf temperatures are checked again once the control has completed a full cycle.
No power at allThere is no light, no hum and nothing on the display. Before concluding the worst, plug a lamp into the same outlet and check the breaker panel. If the outlet is live, the fault lies within the refrigerator and calls for proper electrical testing.
Usual causes
- A breaker has tripped or a GFCI outlet has failed
- The power cord is damaged or the plug is burnt
- The power supply on the main control board has failed
- A thermal overload or a wiring connector at the compressor has burnt
- The display has been left in showroom or demo mode
What we do
Our technician verifies supply voltage first at the outlet and then at the control board. Each stage after that, including the board, the wiring and the compressor circuit, is tested in turn until the interruption is located and repaired.
Compressor not startingThe lights may be on and the fans may be turning, yet the cabinet never cools and the black tank at the rear stays cool when touched. In some cases it hums briefly and then clicks off. Genuine compressor failure is uncommon, which is why we test the start components before anything else.
Usual causes
- The start relay or overload protector has failed
- On models fitted with one, the run capacitor has weakened
- The compressor windings are open or shorted
- The drive board for an inverter compressor has failed
- Years of overheating have seized the compressor mechanically
What we do
Winding resistance is measured across the compressor terminals, and the relay, overload and any inverter board are tested. Should the compressor prove to be the failed part, we set out what the sealed-system repair involves and whether it is sensible for a refrigerator of that age, all before any part is ordered.
Clicks but does not coolAt intervals of a few minutes there is a click from the lower rear corner, sometimes followed by a short hum. That sequence is the compressor attempting to start while the overload protector cuts it off. A faulty start relay, which is a small and inexpensive component, is the usual explanation.
Usual causes
- The PTC element inside the start relay has cracked or burnt
- A worn overload protector is tripping too early
- An extension cord or shared circuit is causing low voltage
- The compressor draws excessive current during start-up
What we do
We remove the relay from the compressor terminals and test it, then examine the overload and measure voltage at the plug while the compressor attempts to start. We then fit a relay and overload kit matched to that compressor and take a current reading once it is running to confirm that it stabilizes.
Condenser coils clogged with dustThe condenser coils release the heat that has been drawn out of the food compartments. When dust or pet hair mats over them, that heat remains in the system. As a result the refrigerator runs for longer, the compressor gets hotter and cooling performance declines gradually.
Usual causes
- The front grille draws in dust and pet hair
- The cabinet is pushed too close to the wall
- A missing kick plate lets warm air recirculate
- The coils have not been cleaned for several years
What we do
With the kick plate or rear access cover removed, the coils and fan blade are brushed and vacuumed clean. We then confirm the condenser fan speed and the compressor's operating temperature to make sure the buildup has not already caused damage.
Condenser fan has stoppedMost frost-free refrigerators use a small fan at the lower rear to draw air across the condenser. If that fan stops, the compressor overheats and its overload switches it off. The cabinet sides may feel warm, and cooling becomes weak.
Usual causes
- The fan motor bearings have seized
- Debris or a loose drain pan is jamming the fan blade
- The motor winding is open
- The control board is not sending voltage to the fan
What we do
We check for voltage at the fan while the compressor is running. If voltage is present but the fan does not turn, the motor is replaced. If there is no voltage, we trace the wiring and the board output and correct the fault.
Show 14 further refrigerator faults
Evaporator fan not runningLocated behind the freezer's rear panel, the evaporator fan moves cold air into both compartments. If it fails, the area of the freezer nearest the coil may remain cold while the fresh-food side warms rapidly. A squealing sound sometimes comes before it stops completely.
Usual causes
- The motor has worn out after years of continuous operation
- Frost from a defrost fault has locked the blade in place
- A faulty door switch tells the fan the door is open
- The fan output on the control board has failed
What we do
We open the freezer panel, test the fan motor and check the door switch that governs it. A worn motor is replaced with a matched part, and if ice was holding the blade, we also repair the defrost circuit so the problem does not recur.
Defrost heater has failedSeveral times a day the defrost heater warms the freezer coil to melt away accumulated frost. Once the heater burns out, that frost hardens into solid ice. A manual defrost restores normal cooling for a time, but the same symptoms eventually return.
Usual causes
- The heater element has opened with age
- The glass tube of the heater has cracked
- Corrosion has affected the wire connector at the heater terminals
- An open defrost thermostat keeps the heater from receiving power
What we do
We check the heater and the defrost thermostat for continuity and confirm that the control really does supply power during defrost. Whichever part has opened is replaced, and we run a defrost cycle on site to show that the coil clears.
Water collecting under crisper drawersWater gathers at the base of the fresh-food compartment, frequently beneath the crispers, or a sheet of ice appears across the bottom of the freezer. Every defrost cycle produces meltwater that is meant to flow through a drain tube into the pan below. When the drain is blocked, that water has no way out.
Usual causes
- Food particles or other debris are blocking the drain opening
- A failed drain heater or clip has allowed the tube to freeze
- Mold or slime has grown inside the tube
- The drain hose behind the rear panel is kinked
What we do
We flush the drain with warm water and clear it using a flexible tool, then inspect whichever heat source keeps the outlet from freezing, either a drain heater or a copper clip. If the tube continues to freeze, the missing or defective heat source is replaced.
Suspected refrigerant leakA slow loss of refrigerant appears as cooling that weakens steadily over a period of weeks. The freezer coil frosts only in part, and the compressor runs continuously. Oily marks on the tubing may also be a sign. Because this involves the sealed system, it requires the correct equipment.
Usual causes
- Corrosion has created pinholes in the evaporator coil
- Vibration or rough handling during a move has cracked the tubing
- A braze joint at the compressor or the drier is leaking
- A knife used to chip away ice has punctured the coil
What we do
Our technician confirms a leak by taking pressure readings on the sealed system and searching the tubing with an electronic detector. The repair is carried out under EPA Section 608 rules, covering refrigerant recovery, brazing, a new filter-drier, evacuation and a measured recharge. Before work begins, we tell you plainly whether the age of the refrigerator justifies the repair.
Control board malfunctionIn newer refrigerators a control board manages the compressor, the fans, the defrost cycle and the dispensers. A failing board can produce unusual combinations of symptoms, for instance fans running while the compressor stays off, or no defrost whatsoever. Although it is seldom the first suspect, a board can and does fail.
Usual causes
- Relay contacts for the compressor or defrost circuit have burnt
- A power surge during a storm or outage has caused damage
- Moisture has entered the board housing
- Many years of heat have cracked solder joints
What we do
Every signal entering and leaving the board is compared with the wiring diagram. That comparison confirms that the board is at fault rather than a sensor sending it incorrect data. Only after that confirmation is a replacement board installed and configured for your model.
Temperature sensor faultThermistors report the temperature of each compartment to the control. When a sensor drifts, the refrigerator runs either too long or not long enough. The display may show incorrect readings or an error code.
Usual causes
- The sensor's resistance has drifted over time
- The wiring is damaged where it runs behind a panel
- Moisture has entered the sensor casing
- The sensor has been dislodged from its mounting clip
What we do
We compare the resistance of each thermistor with the manufacturer's temperature chart. Any sensor reading outside its range is replaced and clipped into its original location so that it measures air temperature accurately.
Repeated clicking at the rearA certain amount of clicking is expected as the thermostat or defrost system switches on and off. Clicking at regular intervals of a few minutes while the cabinet stays warm is not normal. It most often means the compressor is repeatedly trying to start without success.
Usual causes
- The overload protector keeps tripping the compressor
- The start relay is not engaging
- A stopped condenser fan is letting the compressor overheat
- The defrost timer is advancing with an audible click
What we do
We time the clicks and note, at each one, whether the compressor and fans are starting, running or stopping. That comparison leads directly to the relay, the overload, the timer or an overheating condition, which is repaired and then verified through a full running cycle.
Ice dispenser jammedThe motor can be heard but no ice falls, or there is no response whatsoever. Most often the cubes have partly melted and refrozen into a single block inside the bucket. Less often, the auger motor or the door flap has failed.
Usual causes
- A warm spell or a long period without use has fused the ice into a clump
- The auger motor has failed or its gear is stripped
- The solenoid for the dispenser door flap is stuck
- Warm air leaking in has frozen the ice chute shut
What we do
We empty and thaw the bucket, then test the auger and the flap while holding the door switch closed. If the auger motor or the flap solenoid is at fault, we replace it. We also check the freezer temperature, because warm air is frequently the reason the ice fused together.
Ice production very slowIce is produced, but not enough to meet your household's needs. Once the freezer is fully cold, a typical ice maker produces roughly a few pounds a day. Restricted water flow and a freezer that is not cold enough are the usual causes.
Usual causes
- A clogged water filter is reducing the fill volume
- Household water pressure is low
- The freezer is running warmer than its setting
- Sediment has partly blocked the inlet valve screen
What we do
We compare the fill volume with the specification and take a temperature reading beside the ice maker. Where the filter or the valve is restricting flow, we replace it; where the freezer is too warm, we correct the cooling fault behind it.
No water after a filter changeA new filter has gone in and now no water comes through. This is a frequent occurrence. In most cases the filter has not locked fully into place, or air has become trapped in the line.
Usual causes
- The filter has not been rotated all the way into its locked position
- An aftermarket filter has marginally different dimensions
- The protective caps are still on the filter ends
- Air has become trapped in the line after the change
What we do
We reseat the filter and confirm it matches the model's specification, then clear trapped air by operating the dispenser in short bursts. If flow does not return, we test the filter head and the inlet valve.
Frozen water line in doorThe water dispenser has stopped, yet the ice maker carries on working. This normally indicates that the tube passing through the door has frozen. Side-by-side and French-door designs are the most prone to it, particularly when the freezer is set too cold or the door is not sealing properly.
Usual causes
- The freezer is set colder than about −5°F
- A leaking door gasket lets cold air reach the tube
- The tube has been routed against a cold surface
- On models that have one, the door heater has failed
What we do
We thaw the line using warm air and review the freezer setting and the door seal. If the line continues to freeze, we correct its routing or replace the door heater.
Condensation on the outsideDroplets of water form along the door edges or on the cabinet. On muggy Houston days a small amount of this is normal, particularly near an exterior door. Heavy condensation that does not let up generally means warm air is entering or a heater has stopped working.
Usual causes
- The mullion or stile heater between the doors has failed
- A leaking door gasket is letting cold air escape
- The energy-saver switch is on during high humidity
- The door is not closing flush with the cabinet
What we do
We examine the gasket and the door alignment and then check the anti-sweat heater circuit for continuity. If the heater or the gasket has failed, we fit a new one and set the energy-saver control to suit the humidity in the room.
Door does not close properlyThe door drifts back open, or it needs a firm push before it shuts. An unsealed door admits warm, moist air, and frost, condensation and near-constant running tend to follow soon after.
Usual causes
- The cabinet is not tilted back far enough for the door to swing closed
- The door cam or closing mechanism is broken
- The hinge bushings are worn
- A drawer or bin is extended too far
What we do
We level the refrigerator with a slight backward tilt, then inspect the hinge and cam components. Where the bushings have worn or the cam has cracked, new parts are fitted and the door is realigned so that it closes by itself.
Error code displayedMany current refrigerators display a code made of letters and numbers when a fault occurs. The code identifies a circuit, which is not always the same as a single part. A sensor code, for instance, may stem from the sensor, its wiring or the control board.
Usual causes
- A temperature sensor has failed
- A fan motor is not reaching its expected speed
- There is a fault in the defrost circuit
- The display and the main board are not communicating
What we do
We read the active code together with the stored fault history, then test the named circuit from one end to the other. Once the defective component has been replaced, we clear the code and run the appliance to confirm it does not reappear.
Brands
Refrigerator manufacturers we service
Technical notes
Refrigerators in Houston homes
A refrigerator in Houston rarely gets a rest. Its condenser sheds heat into a house that is fighting humidity for most of the year, and a second fridge in the garage does the same job in a space that holds the afternoon heat well into the evening.
Most warm-refrigerator faults come down to airflow and defrost: an evaporator fan that has stopped, a defrost heater or thermostat that has failed and let the coil ice over, or a condenser so matted with dust that the compressor never shuts off. Those can usually be confirmed in one visit, and repaired then when the part is in hand. Sealed-system faults are rarer and costlier, and we say plainly when one is not worth fixing.
Garage refrigerators in a Houston summer
Every refrigerator is built for an ambient range printed in its manual, and an attached garage in July and August can sit above the top of it for weeks. The compressor then runs almost continuously and the fresh-food side drifts warm late in the day. In a hard freeze such as Winter Storm Uri in February 2021, a single-thermostat model in an uninsulated garage can do the opposite: sense the cold, stop running and let its freezer thaw. Tell us which extreme your garage fridge struggles in, because it changes what we test, and no repair turns an indoor model into a garage-rated one.
Sweating doors and soggy gaskets
Some condensation on the door edges is normal on muggy days. Beads of water that never dry, mildew in the gasket folds or a puddle under the doors point instead to a failed anti-sweat heater in the mullion, a gasket that no longer seals, or a door that has dropped out of alignment. We check all three before suggesting a part.
When the power comes back after a storm
A refrigerator that will not restart after a hurricane or a long outage usually has a tripped breaker, a control waiting for a reset, or a start relay or control board damaged by the surge when the grid came back. We test them in that order. A good plug-in surge protector, or whole-home surge protection fitted by an electrician, lowers the risk next time.
What to check first, and where the cost sits
Check that the vents inside the fresh-food section are not blocked by food, that the temperature control has not been bumped, and that the grille at the base is not packed with dust. A freezer that stays cold while the fresh-food side warms usually has a stopped evaporator fan or a defrost fault that has iced over the air channel, not a refrigerator at the end of its life. Call rather than keep trying if the compressor clicks on and off every few minutes without running, if you smell burning at the back, or if water is reaching the floor.
The price follows the part. Fans, defrost heaters and thermostats, door gaskets and water valves are at the lower end; a control board sits in the middle; sealed-system work on a compressor, leak or restriction is at the top, because the refrigerant has to be recovered and recharged under EPA Section 608 rules. On an older freestanding refrigerator that last category often costs more than the refrigerator is worth.
Questions
Refrigerator questions we hear often
Is the food safe in a refrigerator that has been running warm?
USDA guidance is to discard perishable food that has been above 40°F for more than two hours. A thermometer on the middle shelf tells you where you stand. Until the technician arrives, keep the doors shut and move anything that matters into a cooler with ice.
Why is water collecting under my refrigerator?
The most common cause is a blocked defrost drain: meltwater that should reach the pan under the cabinet freezes in the drain or overflows inside and runs out the front. Humid air entering every time the door opens adds to that meltwater. A cracked drain pan, a leaking inlet valve or a loose filter housing are the other usual sources, and we trace the water before replacing anything.
How often should refrigerator condenser coils be cleaned?
In most kitchens once or twice a year is enough. A refrigerator in a garage, in a home with pets, or near a laundry area that sheds lint benefits from more frequent cleaning, because a dusty condenser makes the compressor run longer in heat that is already working against it.
Do you repair built-in and panel-ready refrigerators?
Yes. Built-in columns and panel-ready models from makers such as Sub-Zero, Thermador and Miele are on our brand list. They need to be eased out of their cabinet openings without marking the panels or flooring, which we plan for when you give us the model number at booking.
My refrigerator has not been right since the power came back. Is it damaged?
Sometimes, though often it only needs time and a reset. After a long outage, give the refrigerator twenty-four hours to pull back down to temperature with the doors closed, and check the breaker and any GFCI outlet in the garage, which can trip when power is restored. If it still runs warm, clicks without starting, or the display shows a fault, a surge may have damaged the control board or the compressor start relay, both of which our technicians test directly. A generator that ran the refrigerator on an undersized extension cord can cause similar trouble. Describe the outage when you call (832) 476-8009, because the sequence of events helps the diagnosis.
How much is refrigerator repair in Greater Houston?
A single published price would not be accurate, since the cost is determined by the component that has failed. A valve or switch is an inexpensive repair, whereas a control board or sealed-system work on a refrigerating appliance costs considerably more, and which applies cannot be known until the unit has been examined. Once the diagnosis is complete you are given the exact figure, nothing proceeds without your approval, and the diagnostic fee is then deducted from the total.
How much time does a refrigerator repair usually require?
Approximately 1–3 hours in your home, the diagnosis included. Built-in models require longer, because withdrawing them from the cabinetry without damage forms part of the work. Where a component must be ordered, the expected lead time is given together with the price, and the return appointment is booked before our technician leaves.
Service area
Refrigerator calls across Greater Houston
- Downtown & Midtown
- Montrose
- River Oaks & Upper Kirby
- The Heights
- West University Place
- Bellaire
- Meyerland & Braeswood
- Galleria & Uptown
- Memorial
- Spring Branch
- Energy Corridor
- Clear Lake
- Katy
- Cypress
- Spring
- Humble & Atascocita
- Pasadena
- East End & Fifth Ward
- Northeast Houston & Northshore
- North Houston & Aldine
- Champions & FM 1960
- Cy-Fair & Jersey Village
- Westchase & Sharpstown
- Alief & Southwest Houston
- Medical Center & South Main
- South Park & Sunnyside
- Hobby & Southeast Houston
- Deer Park & La Porte
- Kingwood & Porter
- Tomball
- Sugar Land
- Missouri City
- Richmond & Rosenberg
- Pearland
- Alvin & Angleton
- The Woodlands
- Magnolia & Pinehurst
- Conroe
- League City & Friendswood
- Texas City & La Marque
- Galveston
- Waller & Brookshire
Book a refrigerator diagnosis
Give us the model number and the temperature the fresh-food side is reading, and we will set a three-hour window and bring the parts that model most often needs.