Dryer repair in Houston, with the vent run checked every time.
- Fault found before any price
- One fixed price you approve
- 90-day parts warranty
Phones answered now
- 1You callany hour
- 23-hour windowagreed with you
- 3Fixed pricebefore any work
Free to request · 3 steps
Request a repair appointment
Takes about a minute. There is no charge to submit a request.
- Diagnosis
- The cause is identified before any price is given
- Approval
- One fixed price, and work begins only with your consent
- Hours
- Our phones are answered 24 hours a day
- Warranty
- Parts warranted for 90 days, labor for 30
- 1–2 hours
- Usual duration of a visit
- 30
- Dryer faults documented
- 19
- Manufacturers serviced
- 24/7
- Phones answered
Dryer problems
Dryer problems and what causes them
Choose the symptom. Each card shows the usual causes, starting with the airflow faults behind so many of them.
Drum turns but no heatThe drum rotates and the cycle counts down normally, yet the load comes out as cold as it went in. On an electric dryer, one half of the double-pole breaker may have tripped while the other half still powers the motor. On a gas dryer, the burner may simply not be igniting. With either fuel type, an open thermal fuse is one of the first suspects.
Usual causes
- A thermal fuse that opened because the vent was restricted
- A break in the coil of the electric heating element
- A gas igniter that has cracked or burned out
- Gas valve coils that no longer open the valve
- On an electric model, one leg of the 240-volt supply has tripped
What we do
Our technician begins by confirming the supply: both 120-volt legs of the 240-volt circuit on an electric model, or gas pressure at the valve on a gas model. The thermal fuse, the high-limit thermostat and the element or igniter are then tested individually. The exhaust duct is checked as well, so that a replacement fuse is not lost to the same restriction.
Drying takes two or three cyclesA single load now needs a second or third cycle. The dryer produces warmth, but the clothes remain damp at the end. In the large majority of cases the cause is airflow: the warm, moisture-laden air cannot leave the house quickly enough, so the load never dries efficiently.
Usual causes
- Compacted lint inside the exhaust duct
- A foil transition duct crushed behind the cabinet
- An outdoor hood flap jammed shut or obstructed by a nest
- A cycling thermostat that opens before it should
- Moisture sensor bars coated with residue from dryer sheets
What we do
Airflow is measured at the outdoor hood and the duct is inspected along its length. A blocked or flattened section is cleared or replaced, after which the thermostats and the moisture sensor are tested to confirm that heat is cycling as the manufacturer intended.
Motor hums, drum stays stillYou can hear the motor running or humming, but the drum does not rotate, or the machine does nothing at all. A failed drive belt is the usual explanation, and many owners recall hearing a sharp snap shortly before the problem began.
Usual causes
- A drive belt that has snapped
- An idler pulley that has seized or lost its spring
- Drum rollers that have locked solid
- A centrifugal switch fault preventing the motor from starting
- A door switch that is not completing the circuit
What we do
With the cabinet open, our technician examines the belt, the idler pulley and each drum roller. Whatever has broken or worn is renewed, and the drum is then turned by hand to confirm that it moves freely without any remaining resistance.
Dryer will not startPressing start produces no response, or only a click without any movement. Before booking, confirm that the door is closed completely and that the breaker or fuse has not tripped. Be aware that many models will not run at all once the thermal fuse has opened.
Usual causes
- A faulty door switch
- An open thermal fuse
- A worn start switch
- A motor that fails to start
- A failed control board or timer
What we do
Continuity testing covers the door switch, the thermal fuse and the start switch first; the motor and the control follow. Once the failed component has been identified and replaced, a complete cycle is run to confirm the dryer starts and finishes normally.
Loud rumbling or scraping soundsSqueaks, thumps, scraping and a deep rumble generally originate in the components that support and rotate the drum. These parts wear slowly, so the noise tends to build over weeks. Small objects such as coins, buttons or a stray zipper can also create a good deal of noise as they tumble.
Usual causes
- Drum rollers that have worn flat
- A failing bearing in the idler pulley
- Worn drum glides or a worn rear bearing
- A blower wheel that is loose or striking debris
- Motor bearings that have lost their lubrication
What we do
With the panels removed, the dryer is run so that our technician can locate the source precisely. Each roller, glide and pulley is then checked by hand. Worn components are replaced, frequently as a matched kit, and the dryer is run again to confirm it is quiet.
Cabinet or clothes too hotThe top panel is uncomfortably hot, clothes come out at a scorching temperature, or there is a smell of burning. These are signs that hot air is not being exhausted properly. An overheating dryer is a genuine fire risk, so please leave it switched off until our technician has inspected it.
Usual causes
- A restricted vent that traps heat in the drum
- A cycling thermostat with contacts stuck closed
- A heating element shorting against the cabinet
- A blower wheel that is broken or packed with lint
What we do
Our technician assesses airflow before anything else. Each of the two thermostats, cycling and high-limit, is then tested, and the element is checked for contact with its housing. Once the faulty components are renewed and the vent is clear, exhaust temperature is measured during a test run before the visit ends.
Shuts off within minutesThe dryer starts normally but stops well before the load is dry. Either the motor is overheating and its internal protector is cutting power, or the control has wrongly concluded that the clothes are dry. In some cases the machine will restart once it has cooled.
Usual causes
- The motor's thermal overload is tripping
- The moisture sensor is reporting a dry load
- A blocked vent is causing the high-limit to open
- The door switch is losing contact intermittently
What we do
A meter is connected to the motor and sensor circuits while the cycle runs, so our technician can see exactly which signal is ending it. After the overheating source or the faulty sensor has been corrected, the dryer is allowed to complete a whole cycle without interruption.
Strong burning odor while runningA faint smell of dust burning off during the first minutes of a cycle is normal. A strong odor, or one that grows stronger, is not. Stop the dryer, disconnect its power, and leave it off until it has been examined.
Usual causes
- Lint accumulated around the heating element or burner
- A belt slipping against a seized pulley or drum
- An overheating drive motor
- Burned wiring at the terminal block
What we do
The cabinet is opened and inspected for scorching, melted insulation and lint close to the heat source. Damaged components are replaced, and lint is removed from inside the cabinet and from the exhaust duct.
Only lukewarm heat producedThe dryer produces some heat, but not enough. Loads take a long time and come out warm yet still damp. An element that is only partly working, or a cycling thermostat that opens too early, typically produces this pattern.
Usual causes
- A heating element with a partial break
- A cycling thermostat that opens prematurely
- A weak gas valve coil that lets the burner drop out
- Reduced airflow from a restricted vent
What we do
A thermometer placed in the exhaust shows how the heat rises and falls over roughly ten minutes. Our technician then tests every element coil and the cycling thermostat, along with the valve coils if the dryer burns gas, both cold and at working temperature. The part found to be cutting out early is replaced, and a second exhaust reading confirms the result.
Smell of gas near dryerA brief odor as the burner first lights can occur. A persistent smell of gas is not normal. Where the odor is strong, do not operate any switches; go outside, and once you are clear of the building, telephone the gas utility or 911.
Usual causes
- A loose flexible connector at the gas valve
- A gas valve that does not close completely
- An aged or damaged flexible gas line
- Gas flowing while the burner fails to light
What we do
Our technician checks every gas joint with a leak detector and confirms that the valve shuts off completely. Should a connector or the valve itself be leaking, it is replaced, and the burner is then watched through ignition to make sure it lights cleanly and reliably.
Timer dial stays in placeThe dryer continues to run, but the dial does not move, or it stalls at one position. On models with a mechanical timer, the small timer motor may have failed.
Usual causes
- A burned-out timer motor
- Pitted or burned timer contacts
- No advance signal from the thermostat or moisture sensor
- A broken wire in the timer harness
What we do
Our technician first establishes whether the timer motor receives voltage and whether it rotates when it does. Each set of timer contacts is compared with the model's wiring diagram, and the thermostat or sensor responsible for the automatic-dry advance is checked as well. After the faulty timer or supporting part is renewed, a complete timed cycle is run.
Sensor dry ends at wrong timeSensor or automatic-dry cycles finish while the clothes are still wet, or continue long after they are dry. In most cases the fault lies with the moisture sensor itself or with the control board that interprets its signal.
Usual causes
- Residue coating the moisture sensor bars
- Broken sensor wiring
- A control board that is not reading the sensor
- Very small loads that rarely touch the bars
What we do
The sensor bars are cleaned and the sensor signal is tested at the control board. A broken harness or a failed board is repaired so that automatic cycles finish when the load is actually dry.
Thermal fuse has openedThe thermal fuse is a single-use safety device that opens when the dryer overheats. Fitting a new fuse restores operation, but the repair only lasts if whatever caused the overheating, most often a restricted vent, is corrected at the same time.
Usual causes
- A vent obstructed by lint
- A cycling thermostat stuck closed
- A blower wheel clogged with debris
- A fuse that has weakened with age
What we do
Our technician confirms that the fuse is open, then tests the thermostats and blower and measures airflow at the vent. A new fuse is installed only once the underlying cause has been dealt with.
Electric heating element failedIn an electric dryer, the heating element is a coil of resistance wire held inside a metal housing. Once the coil breaks, the dryer continues to run but delivers only cool air. The break is sometimes visible through the housing.
Usual causes
- A coil that has broken through age
- A sagging coil that has shorted against its housing
- Poor airflow letting the coil run too hot
- A burned terminal connection
What we do
The element is tested for continuity and for any short to its metal housing, and the terminals are inspected for heat damage. A new element is fitted, and vent airflow is measured before the cabinet is closed, since a restricted vent is the most common reason an element fails prematurely.
Igniter does not glowA gas dryer lights its burner with a small igniter that heats until it glows orange. If that glow never appears, the gas is not lit and the dryer produces no heat. Igniters are made of a brittle material and wear out over time.
Usual causes
- A cracked or burned-out igniter
- A flame sensor that is not passing power to the igniter
- An open thermal fuse or high-limit thermostat
- A loose connector at the igniter
What we do
Our technician measures the igniter's resistance and checks for supply voltage at its connector during a call for heat. An igniter that reads open is replaced. If it is never powered, the flame sensor, thermal fuse and high-limit are traced one after another. Finally the burner is ignited several consecutive times to confirm it lights on every attempt.
Burner lights, then goes outThe igniter glows, the flame appears briefly and then goes out, after which the igniter begins to glow again. Weakened gas valve coils are the usual cause, and the dryer may heat normally on its first cycle before failing on later ones.
Usual causes
- Solenoid coils on the gas valve weakened by heat
- A flame sensor that is not switching correctly
- Low gas pressure at the dryer
- Loose connectors on the valve coils
What we do
Weak valve coils frequently pass a cold test and fail only after the cabinet has warmed, so our technician tests them in both conditions. The flame sensor is examined on the same visit. Any worn coil set or faulty sensor is replaced, and the burner is observed over several consecutive heating cycles.
Show 14 further dryer faults
Flame sensor not switchingThe flame sensor confirms to the dryer that the burner has lit. When it malfunctions, the igniter may glow without ever lighting the gas, or the burner may shut down mid-cycle. It is a small component with a considerable effect on how the dryer behaves.
Usual causes
- Contacts that fail to open after ignition
- Contacts that fail to close and let the igniter heat
- Damaged wiring to the sensor
- A sensor that has come loose on the burner tube
What we do
Our technician tests the sensor at room temperature and then watches it switch while the burner operates. A sensor that sticks in either position is replaced and secured firmly to the burner tube. The complete ignition sequence of glow, valve opening, flame and igniter shut-off is verified before the visit ends.
Exhaust vent blockedThe exhaust duct carries hot, humid air out of your home. When it becomes restricted, drying slows, the dryer runs hot and the fire risk rises. Long duct runs, multiple bends and older foil ducting are the most prone to blockage.
Usual causes
- Lint accumulated along the duct
- A nest or debris at the outdoor hood
- A crushed section of duct behind the dryer
- A vent run with too many bends
What we do
Our technician measures airflow at the outdoor hood and inspects every section between the dryer and the exterior wall. Lint is removed with rotary brushes, a sticking hood flap is freed, and crushed or foil sections are replaced with rigid or semi-rigid metal ducting. A second set of airflow and exhaust temperature readings confirms the improvement.
Snapped drive beltThe motor runs but the drum does not turn, and you may have heard a snap. The drive belt wraps around the outside of the drum and is kept under tension by the idler pulley.
Usual causes
- A belt that has cracked with wear
- A seized idler pulley
- Drum rollers creating drag
- Heavy, saturated loads straining the belt
What we do
A belt of the correct size is fitted. With the drum out, our technician also spins the idler pulley and each roller by hand, since a stiff roller or a seized idler is often what overloaded the old belt; any such part is replaced too. A test run with a real load confirms the repair.
Drum rollers worn downA steady thumping or rumbling that continues throughout the cycle usually indicates worn drum rollers. Over time they develop flat surfaces or their internal bearings fail.
Usual causes
- Rollers that have worn flat
- Worn roller axles
- Dry, noisy roller bearings
- Broken retaining clips
What we do
The drum is removed and the rollers, axles and clips are replaced together, as they wear at a similar rate. The belt and idler pulley are inspected while the dryer is open. After reassembly, the dryer is run so you can hear for yourself that the rumble has gone.
High squeal from idler pulleyA high-pitched squeal while the dryer runs frequently comes from the idler pulley. If it is not addressed, the pulley can seize completely and break the drive belt.
Usual causes
- A dry pulley bearing
- A worn pulley wheel
- A stretched spring on the idler arm
- Lint accumulated around the pulley housing
What we do
Turning the idler by hand lets our technician feel for roughness or drag, and the spring tension is checked at the same time. If the pulley is worn, it is renewed; the belt is examined for a glazed surface, and lint is removed from the area around the motor. A brief test run confirms that the squeal has gone.
Drive motor not runningWhen you press start, there is a hum or no sound at all, and neither the drum nor the blower moves. The motor drives both the drum and the blower wheel, so both stop together when it fails.
Usual causes
- Burned-out motor windings
- A failed centrifugal switch
- Seized motor bearings
- A jammed blower wheel
What we do
The blower wheel is first turned by hand to rule out a jam, and then the motor windings and centrifugal switch are tested. Where the motor has failed, a replacement is installed. Our technician also inspects the belt and the blower wheel for damage so that the dryer returns to use in sound condition.
High-limit thermostat faultThe high-limit thermostat cuts the heat if the dryer begins to overheat. When it fails open, the dryer produces no heat. When it fails closed, that protection is lost and the dryer can reach unsafe temperatures.
Usual causes
- Contacts that have burned open
- Repeated overheating caused by a restricted vent
- Contacts welded shut, removing the safety cut-off
- Fatigue from age and heat
What we do
Our technician checks the high-limit for continuity and records exhaust temperature while the dryer runs. A new thermostat is fitted, and the vent and blower wheel are inspected, since a high-limit seldom fails unless the dryer has overheated beforehand.
Cycling thermostat faultThe cycling thermostat maintains the selected drying temperature by switching the heating circuit in and out. A failure can leave the dryer with no heat at all, or with far more heat than the setting calls for.
Usual causes
- Contacts stuck in the open or closed position
- A burned-out bias heater inside the thermostat
- Calibration that has drifted with age
- A loose terminal
What we do
Our technician tests the thermostat cold and then observes it opening and closing during a timed run, with a thermometer placed in the exhaust. A thermostat that holds heat too long or releases it too soon is replaced, and heat cycling is confirmed on each temperature setting.
Moisture sensor bars faultyDuring sensor-dry cycles, two metal bars inside the drum measure how damp the load is. When they are coated or damaged, the cycle ends at the wrong time.
Usual causes
- Bars coated with fabric softener film
- Broken sensor wiring
- A failed sensor input on the control board
- Bars that have loosened in their mounting
What we do
Our technician cleans the bars with rubbing alcohol, then bridges them with a damp cloth while reading the signal at the control board. A damaged harness or bar assembly is renewed. Should the board fail to respond to a valid signal, its input circuit is repaired.
Faulty door switchThe door switch allows the dryer to operate only while the door is closed. When it fails, the dryer may refuse to start, or the drum light may stay on.
Usual causes
- A broken switch actuator
- Worn switch contacts
- A misaligned door catch
- A sagging door hinge
What we do
Our technician tests the switch with a meter and confirms that closing the door presses the actuator all the way in. A switch that has failed is renewed, and the door catch or hinge is adjusted so that the door closes securely every time.
Squeak that follows the drumA squeak that repeats with each rotation of the drum is common in older dryers. It generally comes from worn drum glides, the rear drum bearing or the idler pulley.
Usual causes
- Drum glides that have worn thin
- A dry rear drum bearing
- A worn idler pulley
- A failing motor bearing
What we do
Our technician listens at both the front and rear of the drum and checks each support component. Any worn glide, bearing or pulley is renewed, and lubrication is applied wherever the manufacturer's design permits it.
Rhythmic thump during cycleA regular, repeating thump is usually caused by rollers that have developed flat areas or by a belt that has become damaged. Occasionally it is only a pair of shoes in the load. When the sound appears with every load, a component is responsible.
Usual causes
- Rollers worn with flat areas
- A belt with a lump or crack
- A loose drum felt seal
- Heavy items such as shoes in the load
What we do
The drum is removed so the rollers and belt can be examined closely. Any part with flat areas or lumps is renewed, a felt seal that has come loose is bonded back into place, and our technician turns the drum by hand to check that it rotates smoothly.
Electronic control malfunctionThe display shows unfamiliar codes, buttons do not respond, or the dryer will not start. Although control boards can fail, a faulty switch or sensor can produce almost identical symptoms, so those simpler parts are always tested before the board.
Usual causes
- Damage from a power surge
- A burned relay on the board
- Damage from heat or moisture
- A failed user-interface board
What we do
Once the door switch, thermal fuse and sensors have been ruled out, the board's inputs and outputs are checked against the wiring diagram. If the board is confirmed as faulty, a replacement is fitted and configured for your model, and our technician runs each cycle briefly to verify operation.
Breaker trips when dryer runsThe breaker trips the moment the dryer starts or partway through a cycle. This indicates that something inside the dryer is shorting or drawing excessive current. Please do not keep resetting the breaker.
Usual causes
- A heating element shorted to its housing
- A burned terminal block or power cord
- A motor drawing excessive current
- A weak or undersized breaker
What we do
Our technician tests the element, power cord, terminal block and motor for any short to ground and measures their resistance. After the faulty component is replaced and any heat-damaged wiring is repaired, current draw is measured while the dryer runs. Should the breaker itself prove weak, we will explain this so that a qualified electrician can attend to it.
Brands
Dryer manufacturers we service
Technical notes
Dryers and dryer vents in Houston homes
A dryer moves a lot of hot, wet air, and in many Houston homes that air has a long way to go. Two-story houses and townhomes often put the laundry upstairs or in an interior closet, so the duct climbs through the attic and exits at the roof with several elbows along the way. Lint settles at every bend, the roof cap clogs, and the dryer starts overheating its own safety parts.
That is why a dryer that stopped heating so often has a blown thermal fuse or tripped high-limit thermostat that failed for a reason. Replace the fuse without fixing the airflow and it fails again. We measure airflow at the outside termination, inspect the run we can reach, and then repair the heating, drive or control fault we find, on gas and electric models alike.
Attic and roof vent runs: what we check
On a long attic or roof run, part of the duct is out of reach from the laundry room. When airflow at the termination is weak and the transition duct behind the machine is clear, the restriction is in the attic or at the roof cap. That end of the job belongs to a vent-cleaning contractor or a roofer rather than a dryer part, and we say so before anything is priced.
High-rise and condo dryers
In Downtown, Uptown and Galleria-area high-rises the building often decides how a dryer may exhaust: into a shared riser, through a booster fan, or not at all, which is why many units have condensing or heat-pump dryers. Those designs have their own upkeep: condenser filters, a water container or drain line, and lint screens in more than one place. Let us know the building's rules when you book.
Owner checks, and when to stop using the dryer
Clean the lint screen, pull the dryer forward to look at the transition duct behind it, and feel for strong airflow at the outside hood while the dryer runs. On an electric dryer that tumbles but will not heat, check both halves of the double breaker. Stop using the dryer if you smell burning or gas, if the cabinet is too hot to touch, or if a thermal fuse has already been replaced once: each points to a fault that will not clear on its own and can start a fire.
Thermal fuses, belts, drum rollers, idler pulleys and igniters are the inexpensive end of dryer repair. Heating elements, gas valve coils and drive motors cost more, and control boards the most. A part that failed because of a blocked vent will fail again, which is why the airflow reading comes before the price.
Questions
Dryer questions we hear often
How often should a dryer vent be cleaned?
At least once a year is common fire-safety advice, and more often for long attic or roof runs, large households and homes with pets. Warning signs between cleanings are longer drying times, a cabinet that is hot to the touch, a burning smell, or lint collecting around the outside hood.
My gas dryer lights, then the flame goes out and the clothes stay damp. What fails?
That pattern usually points to the gas valve coils, which weaken with heat and stop holding the valve open once they warm up. A flame sensor that is stuck or an igniter that is slow to reach temperature can produce similar symptoms. We watch the ignition sequence through the sight hole and test each part before replacing one.
Can a dryer be vented into the garage or the attic?
No. Dryer exhaust carries lint and a great deal of moisture, and codes and manufacturers require it to be ducted outdoors. In Houston's humid climate, venting into an attic or garage also feeds mold and mildew. Indoor lint traps sold for this purpose are not a substitute for a proper vent.
Is the vent included when you repair the dryer?
Measuring airflow and checking the transition duct behind the dryer is part of diagnosing any heat or drying-time fault, and clearing or replacing that section is part of the repair when it is the cause. A long attic run or a roof termination may need a vent contractor, and we tell you that before anything is priced.
Service area
Dryer service across Greater Houston
- Downtown & Midtown
- Montrose
- River Oaks & Upper Kirby
- The Heights
- West University Place
- Bellaire
- Meyerland & Braeswood
- Galleria & Uptown
- Memorial
- Spring Branch
- Energy Corridor
- Clear Lake
- Katy
- Cypress
- Spring
- Humble & Atascocita
- Pasadena
- East End & Fifth Ward
- Northeast Houston & Northshore
- North Houston & Aldine
- Champions & FM 1960
- Cy-Fair & Jersey Village
- Westchase & Sharpstown
- Alief & Southwest Houston
- Medical Center & South Main
- South Park & Sunnyside
- Hobby & Southeast Houston
- Deer Park & La Porte
- Kingwood & Porter
- Tomball
- Sugar Land
- Missouri City
- Richmond & Rosenberg
- Pearland
- Alvin & Angleton
- The Woodlands
- Magnolia & Pinehurst
- Conroe
- League City & Friendswood
- Texas City & La Marque
- Galveston
- Waller & Brookshire
Schedule a dryer and vent check
Tell us gas or electric, the model number and how long a load now takes. We'll set a three-hour window and look at the dryer and its vent together.